Tag Archives: dry set brackets

Alternative Siding, Building on Slab, and Ceiling Liner Loading

Today’s Pole Barn Guru answers questions about alternative siding and roofing, whether one can build on an existing slab, and if a ceiling liner can hold insulation.

DEAR POLE BARN GURU: Can you build me a steel wall inside and vinyl siding on the outside with asphalt shingles? PAUL in BLUE GRASS

DEAR PAUL: A beauty of post-frame construction is we can design for virtually any combination of roofing and siding materials you may desire. While I am not a huge fan of steel liner panels, yes – your building can have them along with your vinyl siding. Steel liner panels end up posing challenges with trying to attach things to them, like work benches, cabinets, shelves, etc. Gypsum wallboard (sheet rock) is generally far more affordable as well as easier to make attachments to. And, if 5/8” Type X is used, affords some fire protection.

 

DEAR POLE BARN GURU: Can Hansen build the barn on top of an existing slab? CLYDE in BELLVILLE

DEAR CLYDE: Yes, we can design a complete post frame building kit package to be attached to your existing concrete slab. https://www.hansenpolebuildings.com/2014/12/dry-set-column-anchors/

 

DEAR POLE BARN GURU: My trusses are 8 feet on center will the metal ceiling liner span that 8 feet without sagging if I blow in fiberglass insulation? RODNEY in LAKE ELMO

DEAR RODNEY: No, steel liner panels will sag across an eight foot span. If your building’s roof trusses are not designed to support weight of a ceiling load, then they will sag as well – and, in combination with a snow load, may fail.

 

 

 

Dry Set Brackets on Foundation, Unfinished Jobs, and Engineering

Today the Pole Barn Guru discusses rebuilding on an existing concrete foundation with dry set brackets, unfinished work, and proper engineering.

DEAR POLE BARN GURU: I’ve recently torn down an old machine shed that still has very good 8″ wide by 24″ deep cement foundation walls that I’m thinking about using to erect a new pole barn/machine shed.  Only about 6″ out of the 24″ of the foundation wall is above ground.  Can I erect 4×6 or 6×6 posts to the existing foundation or should I use more of the stick framing techniques?

One additional question on this:  The previous machine shed had a sole plate on the foundation.  Would you normally use a sole plate in a situation like this as well or just attach directly to the concrete? What’s the advantage of using a sole plate?  If I were to use a sole plate and anchored it to the foundation, and then put the posts on top of the sole pate, how would you recommend attach them to the sole plate?

Thanks, MICHAEL

DEAR MICHAEL: Regardless of design solution chosen, it would prudent to have your existing foundation reviewed by a competent local engineer for adequacy. In many areas frost depths are deeper than your foundation, rendering it unable to be reused. Provided your concrete has sufficient depth and strength, a post frame building can easily be mounted to it using dry set anchors (https://www.hansenpolebuildings.com/2014/12/dry-set-column-anchors/).

Bracket manufacturer shows anchors mounted directly to concrete walls and I would imagine this achieves best possible connection without creation of additional hinge points due to sill plate thickness. Sill plate still in place upon top of existing concrete wall, then I would recommend it being cut away where brackets will be located.

DEAR POLE BARN GURU: I had contacted you before regarding a kit but decided I didn’t want to get into a project that big.  I contracted with a local builder from Idaho Falls, Idaho to build my building in Afton, Wyoming.  He seems to have disappeared after setting the posts and framing in the wall girts.  Since he builds very similar to your kits I thought I might inquire to see if you could sell me a partial kit.  What I have is 6×6 posts on 12 foot centers and as I already said, they are framed in with 2×6 girts.

contractors-workingI noticed on your web site you have some buildings in Wyoming.  Do you use vendors for regional distribution?  I can’t imagine shipping everything from MN. JOHN in AFTON

DEAR JOHN: I hate it when a builder pulls things like this it just makes our entire industry look bad. We’ll need specifics of dimensions and features to price balance of your building, as well as what materials you actually have delivered. We have distribution agreements with vendors all across country in order to maximize possible providers and minimize costs of shipping. Your Hansen Pole Buildings’ Designer will be reaching out to you shortly.

 

DEAR POLE BARN GURU: For the post on top of a foundation wall would you recommend 4″ x 6″ or 6″ x 6″ post and would they need to be treated?

Thanks, MICHAEL

DEAR MICHAEL: Second part of your question gets answered first, it would only need to be pressure preservative treated if wood was in contact with concrete. As most commonly available timber sizes are pressure preservative treated, you might very well find treated timbers to be both more readily available and more cost affordable.

As far as size of column – this should be determined by an engineer hired to design your building (or engineered plans provided by your post frame building kit provider). Post size will be influenced by heights of both walls and roof, design wind speeds and wind exposure, snow loads and many other variables. Please do not just take advice from some layperson when it comes to your building’s structural design, rely upon a registered design professional.

 

 

Dear Pole Barn Guru: Can I Use Concrete Brackets with a Foundation?

New!  The Pole Barn Guru’s mailbox is overflowing with questions.  Due to high demand, he is answering questions on Saturdays as well as Mondays.

Welcome to Ask the Pole Barn Guru – where you can ask questions about building topics, with answers posted on Mondays.  With many questions to answer, please be patient to watch for yours to come up on a future Monday segment.  If you want a quick answer, please be sure to answer with a “reply-able” email address.

Email all questions to: PoleBarnGuru@HansenPoleBuildings.com

DEAR POLE BARN GURU: Can you do metal plates with anchor bolts to mount the poles to? CAN I IN CANTON

DEAR CAN I: I will assume you want to either mount columns to an existing foundation wall, or to pour concrete brackets into a future foundation wall. If so, then the answer is yes, we can provide wet-set or dry-set concrete brackets for either situation. For more information on specifics, please read:

https://www.hansenpolebuildings.com/blog/2012/09/concrete-brackets-2/

DEAR POLE BARN GURU: In a previous article, you discuss sliding doors for hangars and mention that you will be writing an article about better options (I assume to include bi-fold doors, stack doors, etc).  Did I miss this article in your index, or have you not yet written it?  Would be very interested in your ideas, as I am looking at constructing a 50×60 hangar with a 40-45’x12′ hangar door.  Have not yet decided whether I will pursue this in a steel or wood frame, thought budget may determine that.  The building is to be located in Boise, ID.  Thanks for your time. GLIDING IN GOLDSBORO

 DEAR GLIDING: You’ve caught me! So many topics to write about, and just not enough days of the week to post them. I’ve just returned from the 2014 Frame Building Expo, where Schweiss Doors (https://www.SchweissDoors.com) was one of the exhibitors. Keep a watchful eye open, as I will be writing about their products and other hangar door options in the very near future.

DEAR POLE BARN GURU: How do I insulate a pole barn cost effectively. COLD IN CONNECTICUT

DEAR COLD: This is one of the most often overlooked areas when people are planning their new pole buildings (as well as one of the most asked questions after construction). Provided you are still in the planning phase, here is some good reading on the subject: https://www.hansenpolebuildings.com/blog/2012/04/climate-controlled/