Sheathing Under Standing Seam Steel
Standing seam steel roofing is manufactured from interlocking roll formed steel panels which are crimped, or snapped, together on site. The panels and seams run vertically from the top of the ridge to the eave side of the roof. The panels are fastened to the framework below by means of either clips or screws which allow the panels to flex in length to compensate for expansion and contraction due to temperature change.
Panels are typically 12 to 18 inches in width, with a narrow tall “rib” along each long side of the panel. These steel panels are rarely structural, as far as their ability to span between roof purlins and carry a snow load, so the majority of manufacturers recommend installation over solid sheathing.
Due to the large flat “pan” between the ribs of the standing seam steel, the panels are prone to oil can, or look wavy. Installation over smooth sheathing surfaces, tends to minimize the effects of oil canning.
American Building Components (www.abcmetalroofing.com) recommends their SL Series® roofing panels be applied over a properly aligned, smooth continuous substrate such as 5/8” or thicker plywood with a suitable moisture barrier between.
How about other manufacturers?
Union Corrugating (www.unioncorrugating.com) merely states, “Install the Advantage-Lok II Standing Seam Roof System on solid decking”, without defining what the solid decking is. When researching the Florida NOA (Notice of Acceptance) for the product, it specifies the decking to be either plywood or wood plank.
Fabral (www.fabral.com) also says to install their Ultra Loc, Horizon 16 and Horizon S panels also use the solid decking term.
This “solid decking” thing continued to perplex me, so I found the UL® online certifications directory at www.floridabuilding.org and see the system for all listed manufacturers (most major United States roll formers) requires:
Substructure — (Plywood) — Plywood decking to be a nominal 5/8 in. thick, exposure sheathing span C-D, 40/20 plywood. All butt joints to be sealed against leakage by using tape and/or caulk or with one-part urethane sealant.”
Planning on using a standing seam steel roofing product? I would most strongly recommend it be installed over 5/8” plywood.
Why? Because the screws will stay in the plywood!
“I have an older (built in the 60’s?) pole building that needs a new roof. It is a typical metal over 2×6 purlins (Purlins 2′ on center, trusses 12′ apart). Current roof is corrugated metal attached with ring shank nails with rubber washers and it leaks (unsurprisingly). The roof had a spray on coating 15 years ago which helps, but again, it leaks and it needs a new roof. I would like to do standing seam roof but since the roof needs to act as a shear diaphragm If I tear off the old metal, I need to sheet the whole thing so those are two substantial projects in their own right (#1 tearing off and then #2 re-sheeting…) . I tried taking a pry bar to find out the difficulty of removing the old nails and it was stuck so securely I ripped the head off the nail rather than nail of the roofing and I estimate there are about 6000 of them! Thinking about it and doing some research, I think it’s possible to go over the existing corrugated roofing with standing seam using wood strips over the corrugated. I’m still concerned about things like condensation occurring if I do that and not sure if it would be unlikely, infrequent, or maybe much worse than what I see now. Obviously frequent and substantial condensation is just going to lead to rot and problems. I’ve looked at the added weight and its about 1.4 lbs per square foot using 24Ga standing seam = pretty trivial compared to snow loads so I think it’s unlikely to be an issue. I’m interested in knowing what advice, experience, and tips the Pole Barn Guru can offer for this situation. Please see attached .pdf for a visual of the scenario at hand. Thanks!?”
DEAR CHAD: Unlike all Hansen Pole Buildings with spans of 40 foot or less (where we have our interior double trusses always designed to be able to support at least a minimal ceiling load of five pounds per square foot), most pole barn trusses are not ordered or designed to support any sort of a ceiling. Many times trusses will have a stamp on them stating truss spacing and loads, if so, you want a Bottom Chord Dead Load of 5 psf or greater. If nothing else, truss manufacturer’s stamp will tell you who fabricated those trusses and you can reach out to them to verify adequacy. If they do not have records available, or are no longer in business, you should engage a Registered Professional Engineer to perform a field inspection to verify adequacy, or to provide an engineered repair.

DEAR DAN: Every Hansen Pole Building is fully engineered to meet or exceed your jurisdiction’s minimum design wind speed requirements (in Ventura county Vult = 100 mph). When wind is a client concern, we always recommend designing to higher than minimum design wind speeds. In many instances, added investments are minimal. Most important is designing to correct wind exposure for your particular site. Most other providers sell Exposure B rated buildings, when many sites are actually Exposure C. For extended reading on wind exposure, please read: 
DEAR POLE BARN GURU: Would it be possible to install a 1/8- 1/4 ‘’ steel plate C-shaped with a “tail” extending from back side to tie a bottom chord and king post together and then cut out a 6’’ section to allow for a garage door opener install. GABE in SIMCOE
DEAR POLE BARN GURU: How do I get drawings quickly for a large pole barn, post frame? JAMES in LITTLE SILVER