Advice on Retro Insulating a Minnesota Pole Barn

Advice on Retro Insulating a Minnesota Pole Barn

Reader RYAN in ELK RIVER writes:

“Happy Thanksgiving! I am working on insulating a pole barn that is on a property I bought. I framed between trusses with 2×6 and plywood on top. I plan to have 3″ of foam blown in. Is there anything I need to be aware of if that is the route I take? Also, in the walls I installed R6 foam board between the purlins, and R 19 fiberglass Batts in the wall cavity. Should I install vapor barrier? I plan on a 42″ steel wainscot around the bottom, with drywall on the rest of the wall and ceiling. 

Thanks for your input! There seems to be lots of different answers out there from the research I’ve done.”

Mike the Pole Barn Guru responds:

In Minnesota, closed cell spray foam has to be so thick to meet R value requirements, it normally makes it impractical as a design solution. If you do opt for spray foam, use closed cell (rather than open) and spray directly to the inside of steel roofing and/or siding, for best results. If you are creating a dead attic space above an OSB ceiling, closed cell spray foam can be applied to underside of OSB, however space above must be adequately ventilated (ideally with eave intake and ridge exhaust points). You also need a provision for condensation prevention on the bottom of roof steel (if one is not already present).

In walls, you want only a single vapor barrier. If your foam boards were properly sealed, then they are your vapor barrier and you should use unfaced batts to fill balance of wall insulation cavity. My preference would be rockwool, rather than fiberglass, as it is not affected by moisture.

Be aware, your building is now going to dry to inside, so be prepared to invest in mechanical dehumidification.

Texas Post Frame Barndominium Insulation

Reader KIMBERLY in LINDEN writes:

“We are building a 52x40x10 post frame home in East Texas.  The entire thing will be living space.  I have been researching as much as possible on the best way to insulate a post frame home with metal siding and roof.  The information is overwhelming and you get a completely different answer depending on who you talk to.  I know not to skimp on insulation, but the consensus on most “barndominium” FaceBook groups is that spray foam is the only way to go.  I have reservations about that, because it may be a superior way to insulate, but it depends almost exclusively on who is doing the actual foam application.  On top of that you need to spend more money on your HVAC system to add the proper ventilation/air exchange.

I want a well insulated home that is specific to the type of building material and location we live in.  To me, “not skimping” on insulation doesn’t mean that it has to be the most expensive insulation either.  

I also know the insulation world is constantly changing and evolving, but what would your recommendation be to insulate our home in East Texas?

Thank you so much for your time!”

Mike the Pole Barn Guru responds:

Your insulation requirements will vary depending upon where you are in East Texas. Climates zone 1 (closest to Gulf) require R-30 ceilings, R-13 walls. Zone 2 requires ceilings to be R-49 and zone 3 (farthest north) goes to R-20 walls. You can look up you county’s climate zone here: https://codes.iccsafe.org/content/IECC2021P1/chapter-3-re-general-requirements#IECC2021P1_RE_Ch03_SecR301. I will cheat for you and tell you Cass County is Climate zone 3A.

For sake of discussion we will assume you have a dead attic space and will be insulating directly above a finished ceiling.  I would ventilate your dead attic space at the eave (air intake) and the ridge (air exhaust). Make provisions for preventing condensation on the underside of roof steel by having some sort of a thermal break. My personal preference is by using an Integral Condensation Control (https://www.hansenpolebuildings.com/2020/09/integral-condensation-control-2/).  You will want to order roof trusses with raised heels (https://www.hansenpolebuildings.com/2012/07/raised-heel-trusses/), so you can get full insulation depth from wall-to-wall with blown in fiberglass. Heel height should be R value of insulation divided by three and add two inches so you can achieve adequate airflow above insulation.

Should you want to condition your attic – delete ventilation, raised heels and the Integral Condensation Control. I would apply closed cell spray foam two inches to the underside of roof steel, then add open cell spray foam to desired R value.

For walls – best results will be from two inches of closed cell sprayed to inside of wall steel, then fill balance of wall cavity with either open cell spray foam, or unfaced batts (ideally stone wool https://www.hansenpolebuildings.com/2013/03/roxul-insulation/). You could also use BIBs to fill (https://www.hansenpolebuildings.com/2011/11/bibs/). Do not place a Weather Resistant Barrier (WRB) under wall steel or a vapor barrier on inside of wall.

As an alternative to spray foam, you can use a WRB between framing and wall steel, then BIBs with an interior vapor barrier or faced batt insulation.

Energy costs are not going to go down, so I would encourage you to err towards more insulation rather than less – and (since most heat loss is upward) invest more into added ceiling insulation than walls.

In warmer, humid climates like yours, your HVAC system should include an Energy Recovery Ventilator (ERV) regardless of what your choice of insulation systems ends up being.