Storage in Trusses

Welcome to Ask the Pole Barn Guru – where you can ask questions about building topics, with answers posted on Mondays.  With many questions to answer, please be patient to watch for yours to come up on a future Monday or Saturday segment.  If you want a quick answer, please be sure to answer with a “reply-able” email address.

Email all questions to: PoleBarnGuru@HansenPoleBuildings.com

DEAR POLE BARN GURU: My shop is in a 30×40 pole barn. I would like to put storage up in the trusses, and have some of the shelves that hang from the ceiling also (really there is no ceiling right now, just the trusses and roof). The trusses span the 30ft and I am worried about putting too much weight on them. I really would rather not have any supports in the middle of my floor…I was wondering if I could just sister up to the truss with some 2x6s or bigger to strengthen them…or should I just limit my upper storage? ONLY IN OHIO

DEAR ONLY: Unless specifically ordered for light storage loading, pole building trusses are rarely constructed so as to support any weight from their bottom chords other than limited electrical and lighting.

As you are considering “beefing up” the existing trusses, you should consult with the company which manufactured the trusses. There is typically a stamp on every truss with the truss company’s name on it. For a nominal fee, they can usually provide an engineered “repair” to upgrade your trusses.

In the event the truss company cannot be located, a Registered Design Professional (RDP – engineer or architect) should be hired to design a repair for you.

Only with one of these two solutions would I be able to recommend placing anything for storage in the truss system.

An alternative may be to build a raised “loft” floor in the building, at the level of, but not supported by the trusses. Again, this is a design best accomplished by a RDP.

DEAR POLE BARN GURU: Hello, I am contractor assembling one of your pole building kit packages.
Would you send me details for flashing the building please?
Need:
-Corner flashing.
-End capping the cut ends at top.
-Where do the corrugated foam strips reside?
-Roof panel overhang on the sides and ends.
-Door trim flashing

Thank you, WISHING IN WASHINGTON

DEAR WISHING: All of these are covered in depth in the Hansen Buildings Construction Guide which was provided to your client after purchase. If your client has not shared it with you, you should ask him for the big white binder which was sent to him. Every piece of trim has a diagram showing what it is along with the code used by the steel company. Detailed drawings show where each piece goes on the building.