Tag Archives: add on to pole barn

Additions, Notching Posts, and Stem Walls

This Monday the Pole Barn Guru answers reader questions about adding to an existing pole barn, the possibility of notching girts into posts, and use of a stem wall on an uneven site.

Hansen Buildings TaglineDEAR POLE BARN GURU: I have an existing 36x36x12 pole barn and would like to do an additional 36-48 roof only build off the back. I used the Oregon ready build plans for my existing barn, built in 2019. My 2 over head doors are on the end wall. I was told by my county official that the ready build plans cannot be added onto because they are stand-alone buildings, but maybe with engineering they could be. Do I need to consider building a separate barn 12′ behind mine or can I possibly get it engineered to be attached? Thank you. CLAYTON in SCAPPOOSE

DEAR CLAYTON: Your county official is correct in stating your existing pole barn is a stand-alone building. It is likely we could engineer and provide your proposed extension, however it may require some modifications to your existing building. A Hansen Pole Buildings’ Designer will be reaching out to you to further discuss your building needs.

 

DEAR POLE BARN GURU: If a DIYer had all the time in the world to build a post frame, could the posts be notched for the girts? MARK in KNOXVILLE

DEAR MARK: My lovely bride and I spent a fair amount of time in Knoxville as our oldest son got his Master’s degree at U.T., lived in Maryville and taught high school at Lenoir City. His youngest sister, used to play summer basketball for Pat Summit (she has a piece of championship basketball court signed by Pat for being best player one year). Beautiful area!

Could and should are not necessarily the same. Sound engineering practice limits notch depths in columns to 1/6th of direction being notched, without requiring more complex engineering review. On a 6×6 (actual dimensions 5-1/2″ x 5-1/2″) this would allow notches to be only 7/8″ deep for an externally mounted girts, or if one was doing bookshelf girts, 7/16″ deep on both sides of column. With externally mounted girts, this could pose challenges with aligning other wall framing members such as splash planks, door headers, etc. For bookshelf girts, nail or screw connections would have to be angled, reducing lateral strength of this connection so as to require extra fasteners.

 

DEAR POLE BARN GURU: My site is not level. Can you build in a stem wall? CHRIS in SEQUIM

DEAR CHRIS: You can either excavate and have a stem wall on the formerly high side, or have a stem wall on the low side and fill. Stem wall can be poured concrete, ICFs or concrete block with wet set brackets, or we can incorporate a Permanent Wood Foundation wall between columns. A Hansen Pole Buildings’ Designer will be reaching out to you for more information about your new post frame building.